Taisho Biomed Instruments Co., Ltd Japanese
  Products   News   About Us   ISO   Links        
Home >> Medical Devices
取扱製品分類
 
Testers
 
Disposables
 
Medical Devices
  Cardiac Pacing Catheters and Leads
  Pressure Measuring System
  For Animal Experiments
   
Others
 
 




Medical DevicesPace Maker-related product
Asynchronous Transesophageal Cardiac Pacer 2007 JP 2007 JP asynchronous transesophageal cardiac pacer
2007JP is a portable wave-compensated asynchronous pacer designed for transesophageal stimulation. In diagnostics it allows for calculating the recovery time of the S-A node, establishing Wenkebach’s point and the second degree atrioventricular block,
Leads for Transesophageal Cardiac monitoring Transesophageal Cardiac Stimulation Leads
FIAB has developed a line of esophageal lead for the diagnosis and therapy of cardiac arrhythmia with several models. All leads adopt silicone tips and the contact area between electrode rings and insulation free from cutting edges provides atraumatic effects during introduction and extraction.
4570 Temporary Cardiac Pacemaker Model 4570 Miro-Pace™ temporary cardiac pacemeker
The Model 4570 is a programmable, dual-chamber, multi-mode temporary cardiac pacemaker capable of multi-mode, multi-parameter operation. It features 11 pacing modes including the most sophisticated DDD mode, crosstalk protection, rapid atrial stimulation from any mode, etc.
▲Top
心カテ関連
Sentron Pressure Interface Sentron Pressure Interface
The Sentron Pressure Measurement System measures blood pressure (with respect to atmospheric pressure) accurately providing an analog high-level output for recording purposes and an analog low-level output for connection to pressure monitoring systems.  
Pressure Tip Catheters Pressure Tip Catheters
The Pressure Tip Catheter delivers maximum accuracy in a whole range of blood pressure applications including dP/dt assessment, gradient measurements (aortic/mitral valves), ventricular pressure measurements, etc.
Blood Pressure Analysis Software System EZ-TAU Blood Pressure Analysis Software
Blood pressure waveform is displayed on the PC screen in real time and the parameter such as dP/dt (Max, Min), TAU (Wiss, Thomp) is analyzed.
Conductance Catheters Conductance Catheters
For easy and high quality cardiac pressure-volume loop measurements obtained by the conductance method
Ventricles Volumetric Device Σ 5 Cardiac Signal Conditioner-Processor
This is an electronic signal conditioner-processor that enables continuous measurement of ventricular volume. Combined with real time measurement of pressure, the Sigma-5 is a perfect system for the study of cardiac function by pressure-volume loop analysis.
▲Top
for animal experiment
Conductance Catheter (for animal)
 
▲Top
Products NewsAbout UsISOLinks